Simons Voss Technologies Palm LDB Version 1.40 Instrukcja Instalacji Strona 212

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 318
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 211
VdS Shunt lock function 3066
Page 25
4.2 Installing the Activation Unit (MA and SA)
You should install the activation unit (AU), no matter whether it is a master activation
unit MA or slave activation unit (SA), above the door case and above the locking
cylinder. In any case, the distance to other SimonsVoss components
must be at least
1 m or approximately 40 inches (refer to the drawing).
Only in this way can you rule out mutual interference influences.
If you install it above the door case, align the activation unit so that the two fastening
screws lie in a horizontal line. This eliminates interference when the door is used in
the normal way. (Refer to the drawing below.)
This installation is done without the antenna extender and with jumper B2 is inserted
(max. range). Because this (simple) installation method allows the system t
Min. 100 cm
(40 inches)
Digital
cylinder
Max. 30 cm (12 inches)
DA
AU
Przeglądanie stron 211
1 2 ... 207 208 209 210 211 212 213 214 215 216 217 ... 317 318

Komentarze do niniejszej Instrukcji

Brak uwag